Call Us :- 08045475630
malharpharmatech@gmail.com
Commercial Biosafety Cabinet

Commercial Biosafety Cabinet

95674 INR/Unit

Product Details:

  • Humidity % <70%
  • Noise Level <65 dB
  • Connectivity Type Standalone, optional data port
  • Filters HEPA filter & Pre-filter
  • Color White & Blue
  • Pressure Range Negative pressure (variable by configuration)
  • Output HEPA filtered air output
  • Click to View more
X

Commercial Biosafety Cabinet Price And Quantity

  • 01 Unit
  • 95674 INR/Unit
  • HEPA filtered, 99.97% removal @0.3 micron
  • Tempered safety glass, sliding type
  • 15-30W, interlocked for safety
  • Seamless welded, corrosion resistant
  • 200-250 mm adjustable
  • 750-800 mm
  • Heavy duty for mobility
  • Audio-visual alerts for filter, airflow, and sash
  • Fluorescent lamp (800-1000 lux)
  • UV lamp interlock with sash position
  • Digital display (Air Velocity, Filter & Lamp status)

Commercial Biosafety Cabinet Product Specifications

  • Front sash with gas spring, UV germicidal lamp, fluorescent lighting, energy efficient, easy to decontaminate
  • Biological safety for laboratory & clinical diagnostics
  • 99.99% @0.3 micron
  • Periodic filter replacement and internal disinfection
  • 0.45 m/s (90 FPM)
  • 220-240V AC, 50 Hz
  • Standard arm entry (approx. 180 mm)
  • Built-in exhaust system
  • <0.01%
  • Minimal (HEPA filtered exhaust)
  • 220 W
  • Class II, Type A2 Biosafety Cabinet
  • Semi-Automatic
  • Microprocessor based
  • Stainless Steel body with safety glass front panel
  • 1500 x 750 x 2100 mm (varies by model)
  • 50 Hz
  • 3 to 6 ft working area (varies by model)
  • Low (220 W nominal)
  • HEPA filtered air output
  • Floor standing
  • HEPA filtration with 0.3 micron retention
  • <65 dB
  • <70%
  • Negative pressure (variable by configuration)
  • HEPA filter & Pre-filter
  • White & Blue
  • Standalone, optional data port
  • 180-250 Kg approx.
  • HEPA filtered, 99.97% removal @0.3 micron
  • Tempered safety glass, sliding type
  • 15-30W, interlocked for safety
  • Seamless welded, corrosion resistant
  • 200-250 mm adjustable
  • 750-800 mm
  • Heavy duty for mobility
  • Audio-visual alerts for filter, airflow, and sash
  • Fluorescent lamp (800-1000 lux)
  • UV lamp interlock with sash position
  • Digital display (Air Velocity, Filter & Lamp status)

Commercial Biosafety Cabinet Trade Information

  • 10 Unit Per Month
  • 15-20 Days
  • Australia, North America, South America, Eastern Europe, Western Europe, Middle East, Central America, Asia, Africa
  • All India

Product Description

  • DOP test port at upstream of HEPA filter integrity test. 
  • Flourscent Light 40 watt  
  • "Exhaust Hepa Filter  0.3 micron   
  • Box Type,Moc:Aluminium,Media:Micro Fiber Glass, Efficiency:99.999% down to 0.3 Micron,Grade:H14   "
  • "Noise/ Vibration Level Less than 80 dB on scale A when Ambient is not 
  • greater than 65 dB on Scale A/Minimum"
  • "Fine filter  5 micron 
  • Flange Type,Moc:Aluminium,Media:Non Woven synthetic Polyester,Efficiency:95% down to 5 Micron,Grade:EU5 "
  • "Hepa Filter   0.3 micron  
  • Box Type,Moc:Aluminium,Media:Micro Fiber Glass,
  • Efficiency:99.999 % down to 0.3 Micron,Grade:H14   "
  • "Vertical Air Flow system 100% exhaust  Air
  • UV Light  18 watt with hour meter 
  • Vertical Sliding Front Door Toughen Glass 8 mm Thik with Motorized door Up down Arrangement 
  •  SS 304 1 mm thik Sheet Matt Finished
  • "Motor Blower designed of statically and dynamically balanced for supply of sufficient 
  • capacity and static pressure to take care of airflow requirement for entire life of 
  • HEPA
  • Double Shaft Motor Blower 0.5 HP, 230 Volt , 1 Phase "
  • Air flow Vertical 100 fpm Intake
  • Electrical Supply 230V AC  1-Phase
  • Fether Touch ON/OFF Push Button for Flourscent light ,Uv Light & Motor Blower with Digital Hour Meter
  • Magnehlic Guage 0-25 mm wc 
  • Stud for Hepa filter fixing
  • Clear  view Toughen  Glass in Side Wall  - 5 mm thik glass"

Other details

 

  • Size :60 x 60 x 60 CM
  • Capacity : 1 Person Working Area Capacity
  • Power : 1 Phase 

 



Advanced Filtration and Safety Controls

Equipped with high-efficiency HEPA and pre-filters, this biosafety cabinet ensures minimal dust and maximum particle removal. Safety interlocks, audio-visual alarms, and a microprocessor-based control system continually monitor and alert users to changes in filter status, airflow, and sash position. The UV lamp is interlocked for added user protection.


User-Focused Design and Operation

The cabinet's ergonomic work surface height (750-800 mm) and digital display provide comfortable, intuitive operation. The sliding tempered glass sash with gas spring facilitates smooth movement, while fluorescent illumination (800-1000 lux) ensures optimal visibility. Heavy-duty caster wheels offer easy relocation, making the cabinet adaptable for any laboratory layout.


Reliable Performance and Easy Maintenance

Constructed from corrosion-resistant stainless steel, this Class II, Type A2 cabinet maintains negative pressure and a consistent flow rate (0.45 m/s), ensuring safe containment. Semi-automatic functionality and low annual maintenance-primarily filter replacement and periodic disinfection-make it a practical choice for high-throughput environments.

FAQ's of Commercial Biosafety Cabinet:


Q: How does the biosafety cabinet maintain a clean and safe work environment?

A: The cabinet uses a combination of HEPA and pre-filters to remove 99.97% of particles as small as 0.3 microns from exhaust air. Negative pressure flow, digital controls, and visual/audible alarms ensure prompt user intervention for airflow and filter issues, maintaining biological containment at all times.

Q: What procedures should be followed for routine maintenance and cleaning?

A: Routine maintenance involves periodic replacement of both HEPA and pre-filters, as well as regular internal disinfection using appropriate cleaning agents. The cabinet's smooth, welded stainless steel surfaces facilitate easy decontamination after each use.

Q: When should the filters in the cabinet be replaced?

A: Filters should be replaced according to manufacturer guidelines or when the integrated audio-visual alarm system indicates reduced efficiency or airflow obstruction. Maintenance schedules may vary depending on laboratory usage intensity.

Q: Where can this biosafety cabinet be installed for optimal performance?

A: This floor-standing cabinet is suited for laboratories and clinical diagnostic settings. It should be placed in a space with stable flooring, adequate ceiling height and minimal air disturbances to maximize containment and filtration efficiency.

Q: What are the benefits of the sash interlock and safety features?

A: The sash position is integrated with safety interlocks to prevent accidental UV lamp activation while open, protecting users from exposure. The sliding tempered safety glass and gas-spring assisted operation further reduce risks and enhance ergonomic access.

Q: How is airflow and filter status monitored on the cabinet?

A: Air velocity, filter, and lamp status are continuously monitored via a microprocessor-controlled digital display. If parameters deviate from optimal ranges, an audio-visual alarm notifies users for corrective action.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Biosafety Cabinet' category



Back to top